[PATCH] hwmon: (smsc47m192) Fix temperature limit and vrm write operations

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Temperature limit clamps are applied after converting the temeprature
from milli-degrees C to degrees C, so the clamp limit needs to be
specified in degrees C, not milli-degrees C.

vrm is an u8, so the written value needs to be clamped to [0, 255].

Cc: Axel Lin <axel.lin@xxxxxxxxxx>
Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx>
---
 drivers/hwmon/smsc47m192.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/hwmon/smsc47m192.c b/drivers/hwmon/smsc47m192.c
index efee4c5..e34918a 100644
--- a/drivers/hwmon/smsc47m192.c
+++ b/drivers/hwmon/smsc47m192.c
@@ -86,7 +86,7 @@ static inline u8 IN_TO_REG(unsigned long val, int n)
  */
 static inline s8 TEMP_TO_REG(int val)
 {
-	return clamp_val(SCALE(val, 1, 1000), -128000, 127000);
+	return clamp_val(SCALE(val, 1, 1000), -128, 127);
 }
 
 static inline int TEMP_FROM_REG(s8 val)
@@ -385,7 +385,7 @@ static ssize_t set_vrm(struct device *dev, struct device_attribute *attr,
 	if (err)
 		return err;
 
-	data->vrm = val;
+	data->vrm = clamp_val(val, 0, 255);
 	return count;
 }
 static DEVICE_ATTR(vrm, S_IRUGO | S_IWUSR, show_vrm, set_vrm);
-- 
1.9.1