Hi Hans, On Mon, Jun 16, 2014 at 08:24:28PM +0200, Hans de Goede wrote: > Testing has revealed that the temperature in the rtp controller of the A10 > (sun4i) SoC has a resolution of 50 milli degrees / step, where as the > A13 (sun5i) and later models have 100 milli degrees / step. > > Add a new sun5i-a13-ts compatible to differentiate the newer models and > set the resolution based on the compatible string. > > This fixes the temperature reported on the A10 being twice as high as expected. Should we maybe add explicit temperature steps property so that we won;t need to patch again if they decided to change resolution again? Thanks. -- Dmitry _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors