On 04/20/2014 05:57 AM, Jean Delvare wrote:
Add support for sysfs attributes temp[1-*]_min_hyst and temp[1-*]_lcrit_hyst. ---
Test results with lm77: lm77-i2c-9-49 Adapter: i2c-diolan-u2c at bus 003 device 013 temp1: +22.5°C (low = +10.0°C, hyst = +12.0°C) (high = +64.0°C, hyst = +62.0°C) (crit = +80.0°C, hyst = +78.0°C) Looks good ... Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors