Re: [PATCH 2/2] sensors: Add support for temp[1-*]_min_hyst and temp[1-*]_lcrit_hyst

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 04/20/2014 05:57 AM, Jean Delvare wrote:
Add support for sysfs attributes temp[1-*]_min_hyst and
temp[1-*]_lcrit_hyst.
---

Test results with lm77:

lm77-i2c-9-49
Adapter: i2c-diolan-u2c at bus 003 device 013
temp1:        +22.5°C  (low  = +10.0°C, hyst = +12.0°C)
                       (high = +64.0°C, hyst = +62.0°C)
                       (crit = +80.0°C, hyst = +78.0°C)

Looks good ...

Guenter