The hysteresis register is shared among both temperature sensors. This means changing one also affects the other. To avoid confusion, established way to express this is to make only the first instance writable and keep all other instances as read-only. Otherwise users may be confused that changing the second writable value also affects the first, while it is more obvious that a writable value may affect a different read-only value. Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx> --- v2: Additional patch drivers/hwmon/lm95245.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/drivers/hwmon/lm95245.c b/drivers/hwmon/lm95245.c index 310e145..1f6a18f 100644 --- a/drivers/hwmon/lm95245.c +++ b/drivers/hwmon/lm95245.c @@ -396,8 +396,7 @@ static SENSOR_DEVICE_ATTR(temp1_crit_alarm, S_IRUGO, show_alarm, NULL, static SENSOR_DEVICE_ATTR(temp2_input, S_IRUGO, show_input, NULL, 2); static SENSOR_DEVICE_ATTR(temp2_crit, S_IWUSR | S_IRUGO, show_limit, set_limit, 7); -static SENSOR_DEVICE_ATTR(temp2_crit_hyst, S_IWUSR | S_IRUGO, show_crit_hyst, - set_crit_hyst, 7); +static SENSOR_DEVICE_ATTR(temp2_crit_hyst, S_IRUGO, show_crit_hyst, NULL, 7); static SENSOR_DEVICE_ATTR(temp2_crit_alarm, S_IRUGO, show_alarm, NULL, STATUS1_RTCRIT); static SENSOR_DEVICE_ATTR(temp2_type, S_IWUSR | S_IRUGO, show_type, -- 1.7.9.7 _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors