Re: [PATCH v3 0/2] Enable lm90 in Tegra30 and Tegra114.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 07/15/2013 10:48 AM, Stephen Warren wrote:
> On 07/12/2013 01:49 AM, Wei Ni wrote:
>> Enable thermal sensor lm90 for Tegra30 Cardhu and Tegra114 Dalmore.
> 
> I have applied the series to Tegra's for-3.12/dt branch.

Actually, I see the following on Dalmore (although Cardhu works):

[   29.448539] lm90 0-004c: Register 0x4 read failed (-121)
[   29.453930] lm90 0-004c: Failed to read convrate register!
[   29.460034] lm90 0-004c: Register 0x3 read failed (-121)
[   29.465408] lm90 0-004c: Initialization failed!

So, there's something wrong here, and I've dropped the patch for
Dalmore. Does this patch actually work for you?

_______________________________________________
lm-sensors mailing list
lm-sensors@xxxxxxxxxxxxxx
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors




[Index of Archives]     [Linux Kernel]     [Linux Hardware Monitoring]     [Linux USB Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Yosemite Backpacking]