Hi Lieven, On Thu, 16 May 2013 09:06:40 +0000, Van Lembergen, Lieven wrote: > Hello jean, guenther, > > Our customer is using the linux driver for the TMP432, but has some extra problems, hope you can help: > 2 issues: > - writing of the max_hyst-field for the last 2 internal sensors > The files to change values is read only ?can they have access? There is only one register internally, where the hysteresis is stored as a relative (or delta) value. So the difference between temp2_crit_hyst and temp2_crit is always the same as the difference between temp1_crit_hyst and temp1_crit. Same for temp3_crit_hyst. That's why only one hyst file is writable. > - extended temperature enabling without patching the init?? Can that be done? The driver doesn't yet support the extended temperature format. This could be added, you can either contribute it as a patch or wait for (or even sponsor) someone to implement it for you. -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors