These NTC resistance to temperature tables should be public, so others such as ab8500 hwmon driver can look up these tables to convert NTC resistance to temperature. Signed-off-by: Hongbo Zhang <hongbo.zhang@xxxxxxxxxx> --- drivers/power/ab8500_bmdata.c | 8 ++++++-- 1 file changed, 6 insertions(+), 2 deletions(-) diff --git a/drivers/power/ab8500_bmdata.c b/drivers/power/ab8500_bmdata.c index f034ae4..53f3324 100644 --- a/drivers/power/ab8500_bmdata.c +++ b/drivers/power/ab8500_bmdata.c @@ -11,7 +11,7 @@ * Note that the res_to_temp table must be strictly sorted by falling resistance * values to work. */ -static struct abx500_res_to_temp temp_tbl_A_thermistor[] = { +struct abx500_res_to_temp temp_tbl_A_thermistor[] = { {-5, 53407}, { 0, 48594}, { 5, 43804}, @@ -29,7 +29,9 @@ static struct abx500_res_to_temp temp_tbl_A_thermistor[] = { {65, 12500}, }; -static struct abx500_res_to_temp temp_tbl_B_thermistor[] = { +int temp_tbl_A_size = ARRAY_SIZE(temp_tbl_A_thermistor); + +struct abx500_res_to_temp temp_tbl_B_thermistor[] = { {-5, 200000}, { 0, 159024}, { 5, 151921}, @@ -47,6 +49,8 @@ static struct abx500_res_to_temp temp_tbl_B_thermistor[] = { {65, 82869}, }; +int temp_tbl_B_size = ARRAY_SIZE(temp_tbl_B_thermistor); + static struct abx500_v_to_cap cap_tbl_A_thermistor[] = { {4171, 100}, {4114, 95}, -- 1.8.0 _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors