On Sun, May 13, 2012 at 07:57:36PM -0400, Ben Kamen wrote: > Ok, after looking around some more -- I should be talking though ipmisensors and not directly communicating with the w83627ehf directly. > > it finds the ipmi interface: > > > Found `IPMI BMC KCS' at 0xca2... Success! > > (confidence 8, driver `ipmisensors') > > > > but then tells me: > > Warning: the required module ipmisensors is not currently installed > > on your system. If it is built into the kernel then it's OK. > > Otherwise, check http://www.lm-sensors.org/wiki/Devices for > > driver availability. > > and I'm using the RHEL 6 released version of lm-sensors: > > lm_sensors.x86_64 3.1.1-10.el6 @base > > > So where do I get ipmisensors? The wiki says I should use ipmitool -- but then how does that integrate? > Please don't top-post. There is openipmi (http://sourceforge.net/projects/openipmi/), but as far as I know it is not actively maintained. Guenter > Thanks, > > -Ben > > > On 05/13/12 5:30 PM, Ben Kamen wrote: > > Hey guys, in response to this email below from Jean, > > > > Can we still use lm_sensors on the winbond IC on the board or should lm_sensors be disabled entirely? > > > > I'm also using an X7SPA-HF and the thermal management goes wonky after a few hours of normal operation. > > > > (temp alarm, fans report erroneous speeds and so forth) > > > > When this started happening, I began to wonder about contention between the IPMI controller onboard and what linux might be trying to do at the same time. > > > > Thanks, > > > > -Ben > > > >> On Fri, 6 Apr 2012 16:08:12 -0400, Justin Piszcz wrote: > >>> Hello, > >>> > >>> Was curious why the max voltage does not show up properly for in4 (VDIMM) > >>> for this X7SPA-HF using lm sensors 3.3.1 or 3.3.2? > >>> > >>> On the sensor reading page for IPMI: > >>> VDIMM Normal 1.84 Volts > >> > >> You should not mix IPMI with native Linux hardware monitoring driver. > >> There is no mutual exclusion on device access, and havoc can (and will) > >> happen. > >> > >>> This is with lm_sensors: > >>> > >>> -- > >>> > >>> $ sensors > >>> w83627dhg-isa-0ca0 > >>> Adapter: ISA adapter > >>> Vcore: +1.16 V (min = +0.72 V, max = +1.39 V) > >>> Vnbcore: +1.04 V (min = +0.94 V, max = +1.16 V) > >>> AVCC: +3.34 V (min = +2.98 V, max = +3.63 V) > >>> +3.3V: +3.34 V (min = +2.98 V, max = +3.63 V) > >>> VDIMM: +1.84 V (min = +1.62 V, max = +0.00 V) ALARM > >>> +5V: +1.25 V (min = +1.13 V, max = +1.38 V) > >>> +12V: +0.75 V (min = +0.67 V, max = +0.83 V) > >>> 3VSB: +3.30 V (min = +2.98 V, max = +3.63 V) > >>> Vbat: +3.06 V (min = +2.70 V, max = +3.30 V) > >>> SYS Temp: +42.0°C (high = +75.0°C, hyst = +70.0°C) sensor = thermistor > >>> CPU Temp: +40.5°C (high = +90.0°C, hyst = +87.0°C) sensor = diode > >>> Case Temp: +24.0°C (high = +80.0°C, hyst = +75.0°C) sensor = diode > >>> $ sensors --version > >>> sensors version 3.3.1 with libsensors version 3.3.1 > >>> > >>> lm_sensors-3.3.2$ prog/sensors/sensors --version > >>> sensors version 3.3.2 with libsensors version 3.3.1 > >>> > >>> w83627dhg-isa-0ca0 > >>> Adapter: ISA adapter > >>> Vcore: +1.16 V (min = +0.72 V, max = +1.39 V) > >>> Vnbcore: +1.04 V (min = +0.94 V, max = +1.16 V) > >>> AVCC: +3.34 V (min = +2.98 V, max = +3.63 V) > >>> +3.3V: +3.34 V (min = +2.98 V, max = +3.63 V) > >>> VDIMM: +1.84 V (min = +1.62 V, max = +0.00 V) ALARM > >>> +5V: +1.25 V (min = +1.13 V, max = +1.38 V) > >>> +12V: +0.75 V (min = +0.67 V, max = +0.83 V) > >>> 3VSB: +3.30 V (min = +2.98 V, max = +3.63 V) > >>> Vbat: +3.06 V (min = +2.70 V, max = +3.30 V) > >>> SYS Temp: +42.0°C (high = +75.0°C, hyst = +70.0°C) sensor = thermistor > >>> CPU Temp: +40.5°C (high = +90.0°C, hyst = +87.0°C) sensor = CPU diode > >>> Case Temp: +24.5°C (high = +80.0°C, hyst = +75.0°C) sensor = CPU diode > >>> > >>> -- > >>> > >>> I also tried hardcoding in4_{min,max}: > >>> > >>> $ cat /etc/sensors3.conf > >>> > >>> chip "w83627ehf-*" "w83627dhg-*" "w83667hg-*" "nct6775-*" "nct6776-*" > >>> > >>> label in0 "Vcore" > >>> label in1 "Vnbcore" > >>> label in2 "AVCC" > >>> label in3 "+3.3V" > >>> label in4 "VDIMM" > >>> label in5 "+5V" > >>> label in6 "+12V" > >>> label in7 "3VSB" > >>> label in8 "Vbat" > >>> label temp1 "SYS Temp" > >>> label temp2 "CPU Temp" > >>> label temp3 "Case Temp" > >>> > >>> set in2_min 3.3 * 0.90 > >>> set in2_max 3.3 * 1.10 > >>> set in3_min 3.3 * 0.90 > >>> set in3_max 3.3 * 1.10 > >>> # http://lists.lm-sensors.org/pipermail/lm-sensors/2010-November/030368.html > >>> set in4_min 1.62 > >>> set in4_max 1.98 > >>> set in7_min 3.3 * 0.90 > >>> set in7_max 3.3 * 1.10 > >>> set in8_min 3.0 * 0.90 > >>> set in8_max 3.0 * 1.10 > >>> > >>> ignore fan1 > >>> ignore fan2 > >>> ignore fan3 > >>> ignore fan4 > >>> ignore fan5 > >>> ignore cpu0_vid > >>> ignore intrusion0 > >> > >> Did you run "sensors -s" after changing the configuration file? > >> > >> -- > >> Jean Delvare > > > > _______________________________________________ > > lm-sensors mailing list > > lm-sensors@xxxxxxxxxxxxxx > > http://lists.lm-sensors.org/mailman/listinfo/lm-sensors > > > -- > Ben Kamen - O.D.T., S.P. > ---------------------------------------------------------------------- > eMail: ben@xxxxxxxxxxxxx http://www.benjammin.net > http://www.linkedin.com/in/benkamen > Fortune says: > Only a fool fights in a burning house. > -- Kank the Klingon, "Day of the Dove", stardate unknown > - - > NOTICE: All legal disclaimers sent to benjammin.net/benkamen.net > or any of it's affiliated domains are rendered null and void on > receipt of communications will be handled/considered as such. > > > _______________________________________________ > lm-sensors mailing list > lm-sensors@xxxxxxxxxxxxxx > http://lists.lm-sensors.org/mailman/listinfo/lm-sensors _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors