On Thu, 2012-05-10 at 15:41 -0400, Björn Gerhart wrote: > Hi Guenter, > > Am 09.05.2012 um 19:43 schrieb Guenter Roeck: > > Hi Bjoern, > > > > Looking through the data sheet, it seems that there is no way to read > > the setting of JP4/Pin 1 in SW. This means I can not really detect if > > UART6 pin 6 overlaps with temp3 or not. Is this correct ? > > Discussed that with my hw folks. Yes, that's correct: sadly there is no way to read out this setting. > Good and bad ... good that I didn't overlook anything, bad that it is undetectable. > > If yes, I > > think we have to drop this patch. > > > ok, agreed. I sent out rev2 which drops the temp3/uart6 overlap detection for IT8783F only. IT8782F doesn't have the strapping option to re-route uart6. Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors