On Thu, 12 Jan 2012 14:23:34 -0800, Guenter Roeck wrote: > Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx> > --- > Documentation/hwmon/lm63 | 6 +++--- > 1 files changed, 3 insertions(+), 3 deletions(-) > > diff --git a/Documentation/hwmon/lm63 b/Documentation/hwmon/lm63 > index 337f7f4..f96eed1 100644 > --- a/Documentation/hwmon/lm63 > +++ b/Documentation/hwmon/lm63 > @@ -61,9 +61,9 @@ PWM modes: manual and automatic. Automatic mode is not fully implemented yet > (you cannot define your custom PWM/temperature curve), and mode change isn't > supported either. > > -The lm63 driver will not update its values more frequently than every > -second; reading them more often will do no harm, but will return 'old' > -values. > +The lm63 driver will not update its values more frequently than configured with > +the update_interval sysfs attribute; reading them more often will do no harm, > +but will return 'old' values. > > The LM64 is effectively an LM63 with GPIO lines. The driver does not > support these GPIO lines at present. Folded into the patch adding the update_interval sysfs attribute, thanks. -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors