Hello :-) A lmsensors3.conf generated by pwmconfig resulted in fancontrol message "Error: file hwmon0/device/fan4_input+hwmon0/device/fan1_input doesn't exist". The motherboard was an ASUS P8H67-V fitted with an S-Flex SFF21E case exhaust fan (3 wire) connected to CHA_FAN2 and a stock Intel Core i3 processor cooler fan (4 wire) connected to CHA_FAN. pwmconfig detected that the Nuvoton NCT6776F controlled both CHA_FAN and CHA_FAN2 via pwm1 (pwm2 controls CPU_FAN; pwm3 seems not to be used). The sensors3.conf generated by pwmconfig included this line: FCFANS= hwmon0/device/pwm1=hwmon0/device/fan4_input+hwmon0/device/fan1_input The space after FCFANS= is irregular but did not seem to cause any problems for fancontrol. Both hwmon0/device/fan4_input and hwmon0/device/fan1_input do exist: root@CW8:~# ls -l /sys/devices/platform/w83627ehf.656/fan[14]_input -r--r--r-- 1 root root 4096 2011-12-03 18:44 /sys/devices/platform/w83627ehf.656/fan1_input -r--r--r-- 1 root root 4096 2011-12-03 18:26 /sys/devices/platform/w83627ehf.656/fan4_inpu Further information: the processor cooler fan was connected to CHA_FAN2 instead of CPU_FAN because pwmconfig could not slow it below 1,100 RPM when it was on CPU_FAN. Here's the pwmconfig output with the processor cooler fan connected to CPU_FAN: PWM 255 FAN 2284 PWM 240 FAN 2112 PWM 225 FAN 2002 PWM 210 FAN 1939 PWM 195 FAN 1872 PWM 180 FAN 1795 PWM 165 FAN 1730 PWM 150 FAN 1674 PWM 135 FAN 1603 PWM 120 FAN 1523 PWM 105 FAN 1456 PWM 90 FAN 1390 PWM 75 FAN 1317 PWM 60 FAN 1231 PWM 45 FAN 1161 PWM 30 FAN 1105 PWM 28 FAN 1110 PWM 26 FAN 1103 PWM 24 FAN 1102 PWM 22 FAN 1104 PWM 20 FAN 1103 PWM 18 FAN 1104 PWM 16 FAN 1102 PWM 14 FAN 1108 PWM 12 FAN 1110 PWM 10 FAN 1111 PWM 8 FAN 1110 PWM 6 FAN 1110 PWM 4 FAN 1111 PWM 2 FAN 1112 PWM 0 FAN 1112 Best Charles _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors