On Fri, 26 Aug 2011 09:19:04 -0700, Guenter Roeck wrote: > ADM1275 supports a second current limit, which can be configured as either lower > or upper limit. Add support for it and report it as either lower or upper > critical current limit. > > Also replace error return code EINVAL for unsupported pages with ENXIO as this > is more appropriate for the observed condition. > > Signed-off-by: Guenter Roeck <guenter.roeck@xxxxxxxxxxxx> > --- > Documentation/hwmon/adm1275 | 8 +++ > drivers/hwmon/pmbus/adm1275.c | 95 ++++++++++++++++++++++++++++++++++++++--- > 2 files changed, 96 insertions(+), 7 deletions(-) > (...) Looks good. Acked-by: Jean Delvare <khali@xxxxxxxxxxxx> -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors