On Thu, 2011-08-11 at 09:00 -0400, J, KEERTHY wrote: > On Thu, Aug 11, 2011 at 4:06 PM, Felipe Balbi <balbi@xxxxxx> wrote: [ ... ] > >> >> + temp = omap_temp_sensor_readl(temp_sensor, > >> >> + temp_sensor->registers->bgap_counter); > >> >> + temp = (temp & temp_sensor->registers->counter_mask) >> > >> >> + __ffs(temp_sensor->registers->counter_mask); > >> > > >> > temp &= ?? > >> > > >> >> + temp = temp * 1000 / (temp_sensor->clk_rate); > >> > > >> > temp *= ?? > >> > >> Need to multiply the temp with 1000 before dividing. > >> temp *= evaluates the RHS first and then multiplies LHS. > > > > temp *= 1000; > > temp /= clk_rate; > > > > Different coding style. I preferred to do it in a single line. > Me too. Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors