An integer overflow occurs in the calculation of RHlinear when the relative humidity is greater than around 30%. The consequence is a subtle (but noticeable) error in the resulting humidity measurement. Signed-off-by: Vivien Didelot <vivien.didelot@xxxxxxxxxxxxxxxxxxxx> Cc: Jean Delvare <khali@xxxxxxxxxxxx> Cc: Jonathan Cameron <jic23@xxxxxxxxx> --- drivers/hwmon/sht15.c | 4 ++-- 1 files changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/hwmon/sht15.c b/drivers/hwmon/sht15.c index a610e78..2c586fc 100644 --- a/drivers/hwmon/sht15.c +++ b/drivers/hwmon/sht15.c @@ -333,11 +333,11 @@ static inline int sht15_calc_humid(struct sht15_data *data) const int c1 = -4; const int c2 = 40500; /* x 10 ^ -6 */ - const int c3 = -2800; /* x10 ^ -9 */ + const int c3 = -28; /* x 10 ^ -7 */ RHlinear = c1*1000 + c2 * data->val_humid/1000 - + (data->val_humid * data->val_humid * c3)/1000000; + + (data->val_humid * data->val_humid * c3) / 10000; return (temp - 25000) * (10000 + 80 * data->val_humid) / 1000000 + RHlinear; } -- 1.7.1 _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors