> Hi Dirk, Hi Guenter, > ... > > +Each channel can be configured indvidually: > > + - pga ist the programmable gain amplifier > > + 0: FS = +/- 6.144 V > > + 1: FS = +/- 4.096 V > > + 2: FS = +/- 2.048 V (default) > > + 3: FS = +/- 1.024 V > > + 4: FS = +/- 0.512 V > > + 5: FS = +/- 0.256 V > > + - data_rate in samples per second > > + 0: 128 > > + 1: 250 > > + 2: 490 > > + 3: 920 > > + 4: 1600 > > + 5: 2400 > > + 6: 3300 > > + > > I thought the data rate only applies for continuous mode, > which you don't use. > What does it do in single shot mode ? It affects the sigma delta integration time and as a result the conversion time. > Thanks, > Guenter Cheers Dirk _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors