On 2/22/2011 10:54 PM, Guenter Roeck wrote: > Hi all, > > while working on NCT6776F support, I realized that there is a fan control > attribute which is not currently supported by the syfs ABI: The number of > fan pulses per revolution. On the NCT6776F, this can be configured in Bank 6, > registers 0x44 to 0x46. Possible values are 0..3 for 4, 1, 2, or 3 pulses > per revolution. > > I encountered the same parameter when working on PMBus devices. At the time, > I thought this was a variant of a fan divisor (ie a divisor of 1, 2, 3, or 4), > but apparently it is different and independent of the fan divisor. How is it any different than the fan divisor? _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors