On Thu, 2011-02-10 at 14:34 -0500, Ian Dobson wrote: [ ... ] > > Maybe if the parameters (_target, _tolerance etc) are invalid in smartfan > mode, we should return invalid-ENOVAL? It would be interesting to be able to > actually control the setpoints, for example on my box running the fans is > silent mode the CPU temperature is abit high for my liking and and standard > mode the fans are too loud. Something in between would be good. > I tend to agree with Jean - it should still be possible to configure other modes prior to actually setting that mode. Having said that, I had a closer look into the NCT6776F datasheet. Turns out that it no longer supports SmartFan III mode, meaning the related registers (pwmX_max_output and pwmX_step_output) no longer exist. I'll have to see what I can do about that. Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors