Hi Guenter, thanks again for your helpful suggestions! I considered them in the new version (see other mail). On 01/19/2011 07:11 PM, Guenter Roeck wrote: >> +#define MAX6639_REG_DEVID 0x3D >> +#define MAX6639_REG_MANUID 0x3E >> +#define MAX6639_REG_DEVREV 0x3F > > Not used/needed ? Not used currently. I would prefer keeping it for future use and documentation in-source of the chip. This way, we have the complete register set listed. Just tell me if we need to remove it for policy reasons etc. Thanks, Roland -- Dipl.-Inf. Roland Stigge SATCOM Technologies ********************************************************** WORK Microwave GmbH Raiffeisenstrasse 12 83607 Holzkirchen Germany Tel: +49 8024 6408-0 Fax: +49 8024 6408-40 roland.stigge@xxxxxxxxxxxxxxxxx http://www.work-microwave.de./ GeschÃftsfÃhrer / Managing Directors: Dr. Andreas Hausotter (CEO), Dr. GÃnter Prokoph (CTO) Sitz / Reg. Office: Holzkirchen, Germany Reg. HRB MÃnchen Nr. 79479 ISO 9001:2008 certificate This message and any attachments may contain confidential information and must not be disclosed to a third party without the prior written consent of Work Microwave GmbH, Germany. If you have received it erroneously, please discard it and contact us by return. ********************************************************** _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors