Hi Sergei, On Thu, 4 Mar 2010 14:37:05 +0200, Sergey Kvachonok wrote: > sensord fails to start with the following messages: > > sensord: Creating round robin database > sensord: Error creating RRD file: /var/log/sensord.rrd: Duplicate DS name: temp1 > > sensors output is like this: > > coretemp-isa-0000 > Adapter: ISA adapter > Core 0: +26.0 C (high = +76.0 C, crit = +100.0 C) > > coretemp-isa-0001 > Adapter: ISA adapter > Core 1: +27.0 C (high = +76.0 C, crit = +100.0 C) > > it8718-isa-0290 > Adapter: ISA adapter > Vcore: +1.01 V (min = +0.00 V, max = +4.08 V) > V_DDR2: +1.90 V (min = +0.00 V, max = +4.08 V) > +3.3V: +3.38 V (min = +0.00 V, max = +4.08 V) > in3: +3.01 V (min = +0.00 V, max = +4.08 V) > in4: +0.38 V (min = +0.00 V, max = +2.10 V) > in7: +3.15 V (min = +0.00 V, max = +4.08 V) > Vbat: +3.18 V > CPU fan: 148 RPM (min = 10 RPM) > System fan: 0 RPM (min = 0 RPM) > temp1: -55.0 C (low = +127.0 C, high = +127.0 C) sensor = thermistor > temp2: -2.0 C (low = +127.0 C, high = +127.0 C) sensor = thermistor > MB temp: +17.0 C (low = +127.0 C, high = +60.0 C) sensor = thermal diode > cpu0_vid: +3.300 V > > I believe the problem is that different sensors provide results with > the same name 'temp1'. > Are there any solutions for this problem? Thanks for reporting. this appears to be a regression in 3.1.2, as I am able to reproduce the bug with this version but not with 3.1.1 on the same machine. Andre, a bisection points to the following change of yours: http://www.lm-sensors.org/changeset/5792/lm-sensors/trunk/prog/sensord Any idea? -- Jean Delvare _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors