Current Temperature for K8 RevG desktop CPUs is a "normalized value" which can be below ambient temperature. As a consequence lots of RevG systems report temperatures like: sensors k8temp-pci-00c3 Adapter: PCI adapter Core0 Temp: +17C Core0 Temp: +3C Core1 Temp: +21C Core1 Temp: +5C being quite below ambient temperature. There are even reports of negative temperature values. This patch corrects the temperature reporting of k8temp for RevG desktop CPUs. Cc: Rudolf Marek <r.marek at assembler.cz> Signed-off-by: Andreas Herrmann <andreas.herrmann3 at amd.com> --- drivers/hwmon/k8temp.c | 17 +++++++++++++++-- 1 files changed, 15 insertions(+), 2 deletions(-) diff --git a/drivers/hwmon/k8temp.c b/drivers/hwmon/k8temp.c index ff12281..b138f79 100644 --- a/drivers/hwmon/k8temp.c +++ b/drivers/hwmon/k8temp.c @@ -49,6 +49,7 @@ struct k8temp_data { u8 sensorsp; /* sensor presence bits - SEL_CORE & SEL_PLACE */ u32 temp[2][2]; /* core, place */ u8 swap_core_select; /* meaning of SEL_CORE is inverted */ + u32 temp_offset; }; static struct k8temp_data *k8temp_update_device(struct device *dev) @@ -116,13 +117,15 @@ static ssize_t show_temp(struct device *dev, to_sensor_dev_attr_2(devattr); int core = attr->nr; int place = attr->index; + int temp; struct k8temp_data *data = k8temp_update_device(dev); if (data->swap_core_select) core = core ? 0 : 1; - return sprintf(buf, "%d\n", - TEMP_FROM_REG(data->temp[core][place])); + temp = TEMP_FROM_REG(data->temp[core][place]) + data->temp_offset; + + return sprintf(buf, "%d\n", temp); } /* core, place */ @@ -176,6 +179,16 @@ static int __devinit k8temp_probe(struct pci_dev *pdev, "wrong - check erratum #141\n"); } + if (((model >= 0x68) && (model != 0xc1)) && + !(model == 0x68) && !(model == 0x6c) && + !(model == 0x7c)) + /* + * RevG desktop CPUs (i.e. no socket S1G1 parts) + * need additional offset, otherwise reported + * temperature is below ambient temperature + */ + data->temp_offset = 21000; + break; } -- 1.6.0.4