Howard Chu wrote:
> The newer AMD X2 Turion (and other) processors appear to have the same thermal
> monitoring capability as K10, but the PCI device IDs for the Northbridge have
> changed. (1022:1303)
>
> I added the new ID to the K10 code posted here
> http://lists.lm-sensors.org/pipermail/lm-sensors/2008-April/022909.html
> and it seems to be working.

By the way, here's the output from my HP dv5z running linux-2.6.27-rc7

root at violino:/usr/src/obj2.6.27/drivers/hwmon# sensors
acpitz-virtual-0
Adapter: Virtual device
temp1:       +59.0?C  (crit = +105.0?C)

k10temp-pci-00c3
Adapter: PCI adapter
temp1:       +59.4?C

-- 
   -- Howard Chu