Hi Nate, On Fri, 13 Jun 2008 11:36:11 -0500, Nate Case wrote: > These changes enable extended mode operation for the ADT7461 which will > allow temperature readings from -64..191 degC instead of the current > limited range of 0..127 degC. I decided to split up the changes so > that the first patch doesn't affect functionality, but just makes > preparations needed to make the second patch easier to follow. Thanks for splitting the changes that way, it will make reviewing them much easier. I'll do that over the week-end, stay tuned. Could you possibly provide a dump of an ADT7461 chip in extended mode? You can obtain it with i2cdump (part of the i2c-tools package). This will help me test your changes. -- Jean Delvare