Update sysfs interface documentation to include energy meters and power meter averaging intervals. Signed-off-by: Darrick J. Wong <djwong at us.ibm.com> --- Documentation/hwmon/sysfs-interface | 12 ++++++++++++ 1 files changed, 12 insertions(+), 0 deletions(-) diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface index f4a8ebc..85e6654 100644 --- a/Documentation/hwmon/sysfs-interface +++ b/Documentation/hwmon/sysfs-interface @@ -328,6 +328,14 @@ curr[1-*]_input Current input value Unit: milliampere RO +********** +* Energy * +********** + +energy[1-*]_input Instantaneous energy use + Unit: microJoule + RO + ********* * Power * ********* @@ -336,6 +344,10 @@ power[1-*]_average Average power use Unit: microWatt RO +power[1-*]_interval Power use averaging interval + Unit: milliseconds + RW + power[1-*]_average_highest Historical average maximum power use Unit: microWatt RO