> On Sun, 02 Sep 2007 14:57:32 +0200, Juergen Bausa wrote:
> > dme1737-i2c-0-2e
> > Adapter: SMBus nForce2 adapter at 4c00
> > V5stby:    +0.00 V  (min =  +0.00 V, max =  +6.64 V)  ALARM
> > Vccp:      +1.10 V  (min =  +0.00 V, max =  +2.99 V)
> > V3.3:      +3.28 V  (min =  +0.00 V, max =  +4.38 V)
> > V5:        +4.94 V  (min =  +0.00 V, max =  +6.64 V)
> > V12:      +11.80 V  (min =  +0.00 V, max = +15.94 V)
> > V3.3stby:  +3.29 V  (min =  +0.00 V, max =  +4.38 V)
> > Vbat:      +2.98 V  (min =  +0.00 V, max =  +4.38 V)
> > Int Temp:    +34?C  (low  =  -127?C, high =  +127?C)
> > CPU Temp:    +29?C  (low  =  -127?C, high =  +127?C)
> > CPU_Fan:     0 RPM  (min =    0 RPM)
> > ERROR: Can't get fan3 data!
> > ERROR: Can't get fan5 data!
> > ERROR: Can't get fan6 data!
> > CPU_PWM:     0      (enable = 1, freq =  25000 Hz)
> > ERROR: Can't get pwm5 data!
> > ERROR: Can't get pwm6 data!
> > cpu0_vid: +1.550 V  (VRM Version 2.4)
>
> Juerg, sensors shouldn't be displaying these errors for optional fans
> and pwms. Can you please provide a patch fixing this? It should be
> pretty easy.

Hmm... An ignore statement would take care of this. Do you have
something else in mind?

...juerg

> Thanks,
> --
> Jean Delvare
>