Hi, writing values < 0?C to TLow and THigh of the LM75 is not supported by the driver, since it strtoul()s instead of strtol()ing. Trivial fix attached. Christian Hohnstaedt -- Christian Hohnstaedt Software Engineer Innominate Security Technologies AG /protecting industrial networks/ tel: +49.30.6392-3285 fax: +49.30.6392-3307 Albert-Einstein-Strasse 14, D-12489 Berlin, Germany http://www.innominate.com Register Court: AG Charlottenburg, HR B 81603 Management Board: Joachim Fietz, Dirk Seewald Chairman of the Supervisory Board: Edward M. Stadum -------------- next part -------------- A non-text attachment was scrubbed... Name: lm75.diff Type: text/x-diff Size: 537 bytes Desc: not available Url : http://lists.lm-sensors.org/pipermail/lm-sensors/attachments/20070724/a73b20fd/attachment.bin