Hi Rudolf, > Yes this is correct W83792D has it vice versa. Please fix that. Patch to fix that below, with updated regression test that gets to the point where echo 0 > pwm_enable should set the fan to 100% and doesn't. Anyway, that's coming up next. -David -------------- next part -------------- A non-text attachment was scrubbed... Name: w83627ehf_pwm_mode_fix.patch Type: application/octet-stream Size: 41270 bytes Desc: not available Url : http://lists.lm-sensors.org/pipermail/lm-sensors/attachments/20060323/ca4609c4/attachment.obj -------------- next part -------------- A non-text attachment was scrubbed... Name: w83627ehf_regression.sh Type: application/x-sh Size: 14765 bytes Desc: not available Url : http://lists.lm-sensors.org/pipermail/lm-sensors/attachments/20060323/ca4609c4/attachment.sh