Following up instructions: See: http://secure.netroedge.com/~lm78/readticket.cgi?ticket=2093 [root at Hahn /]# sensors w83627hf-isa-0290 Adapter: ISA adapter VCore 1: +4.08 V (min = +0.00 V, max = +0.00 V) VCore 2: +4.08 V (min = +0.00 V, max = +0.00 V) +3.3V: +4.08 V (min = +3.14 V, max = +3.46 V) +5V: +5.07 V (min = +4.74 V, max = +5.24 V) +12V: +11.55 V (min = +10.83 V, max = +13.19 V) -12V: +0.82 V (min = -13.16 V, max = -10.90 V) -5V: +1.90 V (min = -5.26 V, max = -4.76 V) V5SB: +5.56 V (min = +4.74 V, max = +5.24 V) VBat: +0.00 V (min = +2.40 V, max = +3.60 V) fan1: 0 RPM (min = 2848 RPM, div = 2) fan2: 0 RPM (min = 2848 RPM, div = 2) fan3: 0 RPM (min = 712 RPM, div = 8) temp1: -48??C (high = +124??C, hyst = +125??C) sensor = thermistor temp2: -48.0??C (high = +80??C, hyst = +75??C) sensor = thermistor temp3: -48.0??C (high = +80??C, hyst = +75??C) sensor = thermistor vid: +0.000 V (VRM Version 8.2) alarms: beep_enable: Sound alarm disabled arp-i2c-0-61 Adapter: SMBus I801 adapter at 1100 [root at Hahn /]# i2cdump 0 0x29 No size specified (using byte-data access) WARNING! This program can confuse your I2C bus, cause data loss and worse! I will probe file /dev/i2c-0, address 0x29, mode byte Continue? [Y/n] y 0 1 2 3 4 5 6 7 8 9 a b c d e f 0123456789abcdef 00: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 10: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 20: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 30: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 40: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 50: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 60: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 70: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 80: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX 90: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX a0: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX b0: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX c0: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX d0: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX e0: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX f0: XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XXXXXXXXXXXXXXXX Met vriendelijke groet / kind regards, Remy de Ruysscher Operations Engineer H. Walaardt Sacr?straat 413 1117 BM Schiphol Oost The Netherlands T +31 (0)20 5025800 F +31 (0)20 5025 801 M +31 (0)6 24748987 E remy.de.ruysscher at marketxs.com <mailto:remy.de.ruysscher at marketxs.com> I www.marketxs.com <http://www.marketxs.com/> ______________________________ DISCLAIMER: This e-mail message is intended for the addressee(s) or authorized recipient only. If you are not the addressee, or an authorized recipient, you are specifically advised that any use, distribution, publication, copying or repetition of this information is prohibited. If you have received this information in error, please notify us immediately (+31 (0)20 50 25 800) and destroy this message.