Hi there, Story so far, test user with a pair of ds1780 chips, patch posted early today fixed main issue, (user patched/install 2.9.1) another issue: >sensors -u gives: >ERROR: Can't get feature `vid' data! >alarms: 4096.00 (alarms) >ERROR: Can't get feature `analog_out' data! is already fixed in CVS lm_sensors2, referred user to that download, o o o third issue is with sensord, and I'm lost -- where to start?: quoting from test user: I edited chips.c in the lmsensors lib, and rebuilt. Cleaned out the distro (Mandrake 10.1) libsensors and sensors stuff. Installed the rebuilt 2.9.1 sensors ds1780-* produces ds1780-i2c-0-2d Adapter: SMBus I801 adapter at ccd0 2.5v: +0.99 V (min = +0.00 V, max = +2.00 V) V1: +1.48 V (min = +1.41 V, max = +1.60 V) 3.3v: +3.30 V (min = +3.08 V, max = +3.52 V) 5v: +3.33 V (min = +3.10 V, max = +3.52 V) 12v: +11.94 V (min = +10.25 V, max = +13.75 V) V2: +1.79 V (min = +1.69 V, max = +1.91 V) F1: 0 RPM (min = 0 RPM, div = 8) F2: 0 RPM (min = 0 RPM, div = 8) T1: +38.0?C (high = +127?C, hyst = +13?C) alarms: Chassis intrusion detection ALARM ds1780-i2c-0-2c Adapter: SMBus I801 adapter at ccd0 2.5v: +2.51 V (min = +2.33 V, max = +2.67 V) V1: +1.67 V (min = +1.57 V, max = +1.80 V) 3.3v: +1.50 V (min = +1.39 V, max = +1.60 V) 5v: +5.00 V (min = +4.66 V, max = +5.34 V) 12v: +11.88 V (min = +10.25 V, max = +13.75 V) V2: +1.98 V (min = +0.00 V, max = +3.59 V) F1: 1940 RPM (min = 703 RPM, div = 8) F2: 1896 RPM (min = 703 RPM, div = 8) T1: +43.0?C (high = +127?C, hyst = +10?C) alarms: Chassis intrusion detection ALARM Much better. sensord stll fails with: May 27 20:01:54 harpo sensord: Chip: ds1780-i2c-0-2d May 27 20:01:54 harpo sensord: Adapter: SMBus I801 adapter at ccd0 May 27 20:01:54 harpo sensord: Algorithm: Unavailable from sysfs May 27 20:01:54 harpo sensord: 2.5v: +1.00 V (min = +0.00 V, max = +2.00 V) May 27 20:01:54 harpo sensord: V1: +1.48 V (min = +1.41 V, max = +1.60 V) May 27 20:01:54 harpo sensord: 3.3v: +3.30 V (min = +3.08 V, max = +3.52 V) May 27 20:01:54 harpo sensord: 5v: +3.33 V (min = +3.10 V, max = +3.52 V) May 27 20:01:54 harpo sensord: 12v: +11.94 V (min = +10.25 V, max = +13.75 V) May 27 20:01:54 harpo sensord: V2: +1.79 V (min = +1.69 V, max = +1.91 V) May 27 20:01:54 harpo sensord: F1: 0 RPM (min = 0 RPM, div = 8) May 27 20:01:54 harpo sensord: F2: 0 RPM (min = 0 RPM, div = 8) May 27 20:01:54 harpo sensord: T1: 38.0 C (limit = 127 C, hysteresis = 13 C) May 27 20:01:54 harpo sensord: Error getting sensor data: ds1780/#61: Can't access procfs/sysfs file May 27 20:01:54 harpo sensord: sensord failed unquote I'm stuck on this one at the moment. Any clues? Thanks, --Grant.