On Tue, 05 Apr 2005 00:31:35 -0700, Philip Pokorny <ppokorny at penguincomputing.com> wrote: >One thing that comes to mind is that the mapping of VID to voltage is >not a simple linear function. The vid voltage mapping is presented in table format on data sheets, and I see absolutely no reason to use anything other than a table lookup, for that technique provides an audit trail back to data sheet. The art of measurement is honesty, not an obfuscated code competition. " The competent programmer is fully aware of the strictly limited size of his own skull; therefore he approaches the programming task in full humility, and among other things he avoids clever tricks like the plague. -- Edsger W. Dijkstra " Cheers, Grant.