Before Value value_min value_max in0 5 3845 in1 2853 3477 in2 3141 3477 in3 2853 3157 in4 5 5 in7 2837 3125 in8 2405 3605 temp1_type 3435 temp2_type 3435 temp3_type 3435 After: Value value_min value_max in0 2661 2949 in1 2853 3477 in2 3141 3477 in3 2853 3157 in4 805 341 in7 2837 3125 in8 2405 3605 temp1_type 3435 temp2_type 3435 temp3_type 3435 -----Original Message----- From: Jean Delvare [mailto:khali at linux-fr.org] Sent: 13 August 2004 19:29 To: Stuart Swindells Cc: sensors at Stimpy.netroedge.com Subject: Re: Ticket 1751 > (...) > Is the output with the fault, it's not possible to get output without > the fault, since as soon as lm_sensors is installed, the fault > appears. Aha, yes, of course. Stupid me. Let's try a different approach then. Please compare (and post) values of files: in*_min in*_max temp*_type before and after the installation of the lm_sensors package. I suspect that writing the voltage limits changes the thermal sensor type as a side effect, but I could be wrong. -- Jean "Khali" Delvare http://khali.linux-fr.org/ -- This email has been verified as Virus free Virus Protection and more available at http://www.plus.net