On Thu, Mar 27, 2003 at 09:32:46PM +0100, Jan Dittmer wrote: > Greg KH wrote: > > >fan_min[1-3] Fan minimum value > >in_min[0-8] Voltage min value. > >pwn[1-3] Pulse width modulation fan control. > >temp_input[1-3] Temperature input value. > Why not start all these counts from 0? Is there any reason to start from > 1? Historical reasons or does the datasheet start the counting from 1? Hm, good point. It looks like most of the values started at 1, with the one exception being the voltage files "in". I don't know why it's this way, history? Perhaps someone from the sensors project can tell us. thanks, greg k-h