Hi, After a lot of time and effort I was finally able to get the sensors.conf set-up for my Dragon+. The values for the Rin/Rf for the -12 and -5 voltages are not correct in the sample sensors.conf. After contacting SOYO, a representative contacted me directly.I questioned the values and she checked on the schematic and found the values for the -12V to be 232K/56K and for -5V 120K/56K.. I stated that I would be sharing this with the lm_sensors group. One other problem exists with lm_sensors and the SOYO MB. The Temp/CPU and Temp/MB are transposed. Of course I can change the labels but the values are still transposed. Any reports to other programs will not be correct. I'm using ksensors-0.7 and the values indeed are reported transpoed. THe MB temp is higher than the CPU temperature. When I know that is not the case. I'm using lm_sensors-2.6.5 and i2c-2.6.5. Everything installed, no errors noted. -- Regards and God speed, Gary The Magic is in the Magician not the wand!