OK, I made that tweak for you. Phil On Tue, Apr 23, 2002 at 03:34:59AM -0700, John M. Choi wrote: > Sorry to bother you, but on the website, it said you were the main PR > guy, so I hope you don't mind. I posted a ticket, #867, for some code to > initialize the Tyan s2460 and have recently figured out that there is a > mistake. Is there a way to update the entry or should I just create a new > ticket? In case, here is the proposed update: > > >From the W83627HF/F pdf datasheet from Winbond, page 93, Revision 1.0 > released Nov. 2000, the last line that writes data, 'outb(0x0a, PORT1);' > should actually be 'outb(0xaa, PORT1);'. > > Basically, I believe this addresses Warning #2, I hope/think/guess. > > What is the best way to change this and what should I do? Should I repost > the updated code in its entirety? > > Thanks. > > John > -- Philip Edelbrock -- IS Manager -- Edge Design, Corvallis, OR phil at netroedge.com -- http://www.netroedge.com/~phil PGP F16: 01 D2 FD 01 B5 46 F4 F0 3A 8B 9D 7E 14 7F FB 7A