LM Sensors Module ADM 1021 running on P4 Xeon (Foster) Procs (Dell Precision 530)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



X Windows may be trying to figure out your monitor via DDC (a I2C bus
on the VGA connector from your video card to your monitor).  It might
be using the wrong bus and confusing your ADM chip?  Or, maybe there
are clashing symbols?  What do you think Mark? 


Phil


On Tue, Jan 08, 2002 at 07:52:35AM -0600, David_Papasan at Dell.com wrote:
> Seem to have gotten it working, If I run Sensors -s -c from the console
> BEFORE X Starts it doesnt shutdown at 60C any longer.
> 
> I tried setting up a section for the ADM1023, it accepted the "Chip" line,
> but regected the label and set lines (didn't see a  listing for it in the
> doc so just used the same format at the 1021.
> 
> Ideas on why starting Sensors -s -c before X Windows would fix everything ?
> or how to get the 1023 to display the 2nd proc's temp ?
> 
> Thanks again
> Knickia Papasan
> Dell Precision IPS
>  
> 
> -----Original Message-----
> From: Mark Studebaker [mailto:mds at paradyne.com]
> Sent: Monday, January 07, 2002 4:23 PM
> To: David_Papasan at exchange.dell.com
> Cc: LM_Sensors developers
> Subject: Re: LM Sensors Module ADM 1021 running on P4 Xeon (Foster)
> Procs (Dell Precision 530)
> 
> 
> The xeon only has one sensor in it, the adm1021 and 1023 each support two.
> So one of the two entries for the 1021 is bogus.
> 
> The driver sees the other processor sensor as a 1023.
> You need to set up an adm1023 section in sensors.conf to get its limits set.
> 
> 
> 
> David_Papasan at Dell.com wrote:
> > 
> > Suggested config Per Sensors-detect
> > 
> > # i2c adapter
> > modprobe i2c-i801
> > 
> > # i2c device
> > modprobe adm1021
> > modprobe eeprom
> > 
> > #modules.conf additions
> > Alias char-major-89 i2c-dev
> > options adm1021 ignore=0,0x18,0,0x19
> > *lookin on the LM Sensors site seems that ignore options were normally
> > bogus, so have tried with and without these*
> > 
> > ***********Sensors default startup (no apps running so temp is
> > low)************************
> > 
> > adm1021-0-18
> > Chassis 34C      (min +20C   Max= +60C )
> > CPU     34C      (min +20C   Max= +60C )
> > 
> > adm1023-0-19
> > 
> > *****************after running Sensor.conf********************
> > 
> > adm1021-0-18
> > Chassis 34C      (min +90C   Max= +105C )
> > CPU     34C      (min +90C   Max= +105C )
> > 
> > adm1023-0-19
> > 
> > ************sensors.conf*****************************
> > Chip "adm1021-*"
> > 
> > label temp "Chassis"
> > label remote_temp "CPU"
> > 
> > set temp_low    90
> > set temp_over   105
> > set remote_temp_low     90
> > set remote_temp_over    105
> > 
> > Also if you add the options ignore 0,0x18 gets rid of the adm1021 readout,
> > 0,0x19 gets rid of the adm1023
> > 
> > Also have tried doing a force_max1617, will also try force_max1617a.
> > 
> > Thanks for any insight you can provide.
> > Knickia Papasan
> > Dell Precision IPS
> > 
> > -----Original Message-----
> > From: Mark Studebaker [mailto:mds at paradyne.com]
> > Sent: Monday, January 07, 2002 12:17 PM
> > To: David_Papasan at exchange.dell.com
> > Cc: lm78 at stimpy.netroedge.com
> > Subject: Re: LM Sensors Module ADM 1021 running on P4 Xeon (Foster)
> > Procs (Dell Precision 530)
> > 
> > we don't support the 87365.
> > 
> > we would need the output of 'sensors'
> > (before and after running 'sensors -s')
> > and the contents of /etc/sensors.conf
> > to see what the problem is with setting the limits on the xeons.
> > 
> > mds
> > 
> > David_Papasan at Dell.com wrote:
> > >
> > >         We have a user running LM_Sensors under Linux 7.1 that is
> > > experiencing thermal shutdowns at normal temperatures. The system is a
> > Dell
> > > Precision 530, P4 Xeon, Intel 860 Chipset, National Inst. PC87365 HW
> > > monitoring. LM Sensors detects an Analog devices 1021, which would be
> > fairly
> > > accurate because the xeon's have Max 1617 chips on them. Dell's normal
> > > monitor is that the Max monitors the chip, and works with the PC87365,
> the
> > > bios has preset thermal limits ( 70C clock throttle, 90C Thermal warning
> > and
> > > shutdown counter set to 90second, 105C quickshutdown).
> > >
> > >         What seems to be happening is
> > > 1.) ADM1021 loads and resets temps to 20C warning, 60C shutdown
> > > 2.) If you run Sensors -c it sets the desired temperature on the
> Secondary
> > > Proc, but leaves the Primary at 20C/60C.
> > > 3.) after 7 mins or so of 100% CPU utilization the system will do a
> dirty
> > > shitdown and the bios indicates a thermal event was reported (even thou
> if
> > > you monitor with Sensors the Temp only got to 60C)
> > >
> > > I dont think sensors is handling the primary proc right in a dual CPU
> > > situation because if I remove the second CPU Sensors is not seeing any
> of
> > > the max chips. But if I dont load ADM 1021 the system will run at 100%
> CPU
> > > without error.
> > >
> > > Is there a module that will work with the PC87365 ? or a way to monitor
> 2
> > > Max 1617 chips and set the temperature accordingly ?
> > >
> > > Thanks
> > > Knickia Papasan
> > > Dell Precision IPS

-- 
Philip Edelbrock -- IS Manager -- Edge Design, Corvallis, OR
   phil at netroedge.com -- http://www.netroedge.com/~phil
 PGP F16: 01 D2 FD 01 B5 46 F4 F0  3A 8B 9D 7E 14 7F FB 7A