On 02/01/2012 08:05 AM, Rajkumar Manoharan wrote:
In the following scenario, where the distance b/w STA and AP is ~10m or in a shield environment by placing an attenuator with reduced AP txpower, the station started reporting with beacon loss and got disconnected whenever the chariot endpoint was initiated with BiDi traffic. In such state, two different stuck cases were observed. * rx clear is stuck at low for more than 100ms * dcu chain and complete state is stuck. This patch detects the stuck state if the beacons are not received for more than 300ms. In the above matching conditions, trigger a chip reset to recover. This issue was originally reported in 3.0 kernel with AR9382 chip by having two stations associated with two different APs in the same channel and was attenuated/controlled by Azimuth ADEPT-n box.
Can't the AP be configured for larger beacon intervals? Maybe have it be some multiple of that instead of a fixed 300ms? Thanks, Ben -- Ben Greear <greearb@xxxxxxxxxxxxxxx> Candela Technologies Inc http://www.candelatech.com -- To unsubscribe from this list: send the line "unsubscribe linux-wireless" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html