Hello, I am working on a TI-OMAP3 + AR9170 based AP. The carl9170 driver is version 1.9.2 and the firmware is version 1.9.4. The rest of the system is a couple of months old compat-wireless configuration on a 2.6.37 kernel. The network is pretty usable when no clients enable WLAN power save. However, when power save is enabled, I see lots of disconnects and instability in the system. The clients are using legacy power save mechanisms (using 'null' packets to indicate going in and coming out of power save to the AP). Most of the disconnects seem to be caused by beacons that update the TIM IE but not the overall length. The result is a corrupted RSN IE (e.g. the IE length says 20 bytes but the IE is only 19 bytes in size) which causes the clients to disconnect. This problem lasts for only one beacon (i.e. the next beacon has the right size) but it is enough to cause the clients to disconnect. Is there a way to fix this? Another problem when power save is enabled is the large and unpredictable latency. I understand how enabling power save can increase latency but my ping times go from 3-4 ms without power save to a wide range of 3 ms - 3 s after I enable power save. I am trying smaller beacon intervals to reduce this latency but even at a beacon interval of 25ms, I get ping times of up to ~400 ms. How do I reduce this wide variation in latency. Thanks for your help. Regards, - Harshal -- To unsubscribe from this list: send the line "unsubscribe linux-wireless" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html