On Tue, 2022-07-19 at 14:35 +0200, Baligh Gasmi wrote: > Add a worker scheduled periodicaly to calculate the busy time average of > the current channel. > > This will be used in the estimation for expected throughput. > I really don't think you should/can do this - having a 1-second periodic timer (for each interface even!) is going to be really bad for power consumption. Please find a way to inline the recalculation with statistics updates and/or queries. johannes