On Thursday, 9 December 2021 10:21:02 CET Sven Eckelmann wrote: > Tested-by: Sven Eckelmann <sven@xxxxxxxxxxxxx> I would like to retract this again because it seems like the firmware is now hanging all the time when the default runtime-pm/deep-sleep settings are used. [ 521.553436] mt7921e 0000:05:00.0: Message 40000002 (seq 12) timeout [ 521.559884] mt7921e 0000:05:00.0: chip reset [ 521.661983] mt7921e 0000:05:00.0: HW/SW Version: 0x8a108a10, Build Time: 20211129210838a [ 521.661983] [ 521.684088] mt7921e 0000:05:00.0: WM Firmware Version: ____010000, Build Time: 20211129210917 [ 521.723561] mt7921e 0000:05:00.0: Firmware init done This doesn't seem to happen that often when I perform a echo 0 > /sys/kernel/debug/ieee80211/phy0/mt76/runtime-pm echo 0 > /sys/kernel/debug/ieee80211/phy0/mt76/deep-sleep before setting up the interfaces. But even then, on the first "ip link set up dev mon0" (not only for mon0 - also for wlan0/...) it will crash with: [ 806.731357] mt7921e 0000:05:00.0: Message 00000046 (seq 4) timeout [ 806.737730] mt7921e 0000:05:00.0: chip reset RTNETLINK answers: Connection timed out [ 806.867666] mt7921e 0000:05:00.0: HW/SW Version: 0x8a108a10, Build Time: 20211129210838a [ 806.867666] [ 806.888441] mt7921e 0000:05:00.0: WM Firmware Version: ____010000, Build Time: 20211129210917 [ 806.928204] mt7921e 0000:05:00.0: Firmware init done But when I then set up the device again then it seems to work. This is the case for monitor and managed interfaces. I've used commit 678071ef7029 ("mt76: mt7615: clear mcu error interrupt status on mt7663") in mt76.git for this. Kind regards, Sven