Since thermal_notify_framework is no longer supported/implemented remove the entry from sysfs-api.rst. --- Documentation/driver-api/thermal/sysfs-api.rst | 12 +----------- 1 file changed, 1 insertion(+), 11 deletions(-) diff --git a/Documentation/driver-api/thermal/sysfs-api.rst b/Documentation/driver-api/thermal/sysfs-api.rst index e7520cb439ac..d5b6ca812873 100644 --- a/Documentation/driver-api/thermal/sysfs-api.rst +++ b/Documentation/driver-api/thermal/sysfs-api.rst @@ -743,17 +743,7 @@ This function returns the thermal_instance corresponding to a given {thermal_zone, cooling_device, trip_point} combination. Returns NULL if such an instance does not exist. -4.3. thermal_notify_framework ------------------------------ - -This function handles the trip events from sensor drivers. It starts -throttling the cooling devices according to the policy configured. -For CRITICAL and HOT trip points, this notifies the respective drivers, -and does actual throttling for other trip points i.e ACTIVE and PASSIVE. -The throttling policy is based on the configured platform data; if no -platform data is provided, this uses the step_wise throttling policy. - -4.4. thermal_cdev_update +4.3. thermal_cdev_update ------------------------ This function serves as an arbitrator to set the state of a cooling -- 2.25.1