On 2020-11-06 16:11, Johannes Berg wrote:
On Mon, 2020-11-02 at 21:44 +0200, Kalle Valo wrote:
vnaralas@xxxxxxxxxxxxxx writes:
> On 2020-10-22 13:30, Arend Van Spriel wrote:
> > On 10/21/2020 7:19 PM, Kalle Valo wrote:
> > > vnaralas@xxxxxxxxxxxxxx writes:
> > >
> > > > On 2020-09-29 13:10, Kalle Valo wrote:
> > > > > Johannes Berg <johannes@xxxxxxxxxxxxxxxx> writes:
> > > > >
> > > > > > On Mon, 2020-08-24 at 13:56 +0530, Venkateswara Naralasetty wrote:
> > > > > > > AP power save feature is to save power in AP mode, where AP goes
> > > > > > > to power save mode when no stations associate to it and comes out
> > > > > > > of power save when any station associate to AP.
> > > > > >
> > > > > > Why do you think this requires a vendor command? I mean, that seems
> > > > > > like
> > > > > > fairly reasonable - even by default - behaviour?
> > > > >
> > > > > I have not studied the details, but doesn't AP power save break
> > > > > normal
> > > > > functionality? For example, I would guess probe requests from
> > > > > clients
> > > > > would be lost. So there's a major drawback when enabling this,
> > > > > right?
> > > >
> > > > This AP power save feature will not break any functionality, Since
> > > > one
> > > > chain is always active and all other chains will be disabled when
> > > > this
> > > > feature is enabled. AP can still be able to beacon and receive probe
> > > > request from the clients. The only drawback is reduced network range
> > > > when this feature is enabled. Hence, we don't want to enable it by
> > > > default.
> > >
> > > Yeah, we really would not want to enable that by default. But what
> > > should be the path forward, a vendor command or a proper nl80211
> > > command? Any opinions?
> >
> > I would go for a proper nl80211 command or just add an attribute for
> > use in NL80211_CMD_START_AP or deal with NL80211_CMD_SET_POWERSAVE
> > when operating in AP mode.
> >
> Sure, I will go with the existing NL80211_CMD_SET_POWERSAVE and I will
> send next version.
Better to wait first so that we have concensus on this. And need to
check if NL80211_CMD_SET_POWERSAVE is even suitable for AP mode.
I suspect that SET_POWERSAVE might be confusing.
Perhaps just with an attribute used in START_AP (and CHANGE_BEACON if
needed) would be sufficient?
Actually this ap power save configuration is applicable for per pdev.
So, I don't think we can use START AP command here.
I would prefer to go with a new NL80211 command. Please share your
thoughts on this.
johannes