When the network interface goes down while a scan request is still pending that can't be stopped due to firmware hickups, wcn->scan_req remains set, even though the hardware is deinitialized. This results in -EBUSY for all scan requests after the interface was brought up again. Fix this by explicitly completing pending scan requests in wcn36xx_stop(). Signed-off-by: Daniel Mack <daniel@xxxxxxxxxx> --- drivers/net/wireless/ath/wcn36xx/main.c | 13 +++++++++++++ 1 file changed, 13 insertions(+) diff --git a/drivers/net/wireless/ath/wcn36xx/main.c b/drivers/net/wireless/ath/wcn36xx/main.c index 749aef3e2b85..08b6939d3f57 100644 --- a/drivers/net/wireless/ath/wcn36xx/main.c +++ b/drivers/net/wireless/ath/wcn36xx/main.c @@ -353,6 +353,19 @@ static void wcn36xx_stop(struct ieee80211_hw *hw) wcn36xx_dbg(WCN36XX_DBG_MAC, "mac stop\n"); + cancel_work_sync(&wcn->scan_work); + + mutex_lock(&wcn->scan_lock); + if (wcn->scan_req) { + struct cfg80211_scan_info scan_info = { + .aborted = true, + }; + + ieee80211_scan_completed(wcn->hw, &scan_info); + } + wcn->scan_req = NULL; + mutex_unlock(&wcn->scan_lock); + wcn36xx_debugfs_exit(wcn); wcn36xx_smd_stop(wcn); wcn36xx_dxe_deinit(wcn); -- 2.14.3