On Sat, 2007-06-02 at 13:51 -0500, Larry Finger wrote: > The initial rate for STA's using rc80211_simple is set to the last > rate in the rate table. This is too fast for the bcm43xx-mac80211 > driver. To correct this situation without affecting any other driver, > an initial_rate parameter is added to the rc80211_simple module. This > parameter is set to 10 times the desired initial rate. If the parameter > is zero or not set, the original behavior is kept. If the parameter > does not match a valid rate, the first rate in the table will be set. I think I'd like to see your "start at 1M" patch merged rather than this new API. If rc80211_simple migrates quickly enough then it'll migrate to 54M quickly without causing much performance loss, if not we need a better rate control algorithm anyway. johannes