Re: [RFC PATCH 0/6] Support ROHM BD96801 scalable PMIC

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 4/2/24 16:07, Matti Vaittinen wrote:
Another "oddity" is that the PMIC has two physical IRQ lines. When I
last wrote this patch in 2021 I had some naming collison in debugfs for
the IRQ domains. Back then I used:
irq_domain_update_bus_token(intb_domain, DOMAIN_BUS_WIRED);
to work-around the issue. Now, when rebasing to v6.9-rc1 the naming
collision was gone and things seemed to work. However, it'd be great if
the IRQ code in MFD driver was reviewed by greater minds :)

It appears my statement "things seemed to work" is a bit too optimistic. I am afraid my approach of having two separate IRQ domains for one device (and DT-node) is just somehow fundamentally wrong. It'd be great to learn what's the correct "ideology" here.

It appears the naming collision is still there. My config just had the CONFIG_GENERIC_IRQ_DEBUGFS disabled. Enabling it shows the same naming collison: debugfs: File ':ocp:interconnect@48000000:segment@100000:target-module@9c000:i2c@0:pmic@60' in directory 'domains' already present!

If I'm not mistaken the debugfs file name is generated from the device-tree node path+name. This is a subtle hint that it is not expected there are more than 1 IRQ-domain / device. I guess this kind of makes sense if we can have more than 1 HWIRQ handled by a single domain (I don't recall having to ever write such domain/IRQ-controller before, but I think it should be possible).

I have now 3 new questions =)

1. Should we be able to have more than 1 IRQ domain / device?
2. Should regmap_irq support having more than 1 HWIRQ
3. If answer to 1 is "no" - should we protect against this somehow? (see why below).

When CONFIG_GENERIC_IRQ_DEBUGFS is disabled, adding the two IRQ controllers with own IRQ domains (intb and errb here) to a single device is seemingly successful. I see no complaints / errors. Also, most of the IRQs seem to work - but not all. In my case trying to issue:

cat /proc/interrupts

will oops. Also, looking in the /sys/kernel/irq/ lists folders for all the "intb" and "errb" IRQs - but reading the files contained in these directories will cause an oops for all "errb" interrupts except for the first 16.

Finally, if I use the
irq_domain_update_bus_token(intb_domain, DOMAIN_BUS_WIRED);

to add "-1" at the end of the "intb" - domain name resulting domains:

:ocp:interconnect@48000000:segment@100000:target-module@9c000:i2c@0:pmic@60
:ocp:interconnect@48000000:segment@100000:target-module@9c000:i2c@0:pmic@60-1

then it seems that reading the IRQ information from the /proc/interrupts works as expected. Here I am making a wild guess that the name of the domain is used as a key for some data-lookups, and having two domains with a same name will either overwrite something or cause wrong domain data to be fetched. (This is just guessing for now).

Any tips, hints or thoughts on this?

Yours,
	-- Matti

--
Matti Vaittinen
Linux kernel developer at ROHM Semiconductors
Oulu Finland

~~ When things go utterly wrong vim users can always type :help! ~~





[Index of Archives]     [Linux ARM Kernel]     [Linux ARM]     [Linux Omap]     [Fedora ARM]     [IETF Annouce]     [Security]     [Bugtraq]     [Linux]     [Linux OMAP]     [Linux MIPS]     [eCos]     [Asterisk Internet PBX]     [Linux API]

  Powered by Linux