On 22/05/18 19:47, Ray Jui wrote:
Update the SP805 binding document to add optional 'timeout-sec'
devicetree property

Signed-off-by: Ray Jui <ray.jui@xxxxxxxxxxxx>
Reviewed-by: Scott Branden <scott.branden@xxxxxxxxxxxx>
---
  Documentation/devicetree/bindings/watchdog/sp805-wdt.txt | 2 ++
  1 file changed, 2 insertions(+)

diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
index edc4f0e..f898a86 100644
--- a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
+++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
@@ -19,6 +19,8 @@ Required properties:
Optional properties:
  - interrupts : Should specify WDT interrupt number.
+- timeout-sec : Should specify default WDT timeout in seconds. If unset, the
+                default timeout is 30 seconds

According to the SP805 TRM, the default interval is dependent on the rate of WDOGCLK, but would typically be a lot longer than that :/

On a related note, anyone have any idea why we seem to have two subtly different SP805 bindings defined?

Robin.