Re: [PATCH 2/3] watchdog: at91sam9_wdt: avoid spurious watchdog reset during init

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 11/03/2013 09:52 AM, Boris BREZILLON wrote:
Use the min_heartbeat value instead of the calculated heartbeat value for
the first watchdog reset to avoid spurious watchdog reset.

Resetting the watchdog counter during init might lead to a watchdog fault
reset because the watchdog counter has to be running for at least
min_heartbeat.

Resetting the watchdog counter after heartbeat might lead to a watchdog
timeout reset because the watchdog counter is running for more than
max_heartbeat time.

Using min_heartbeat instead of heartbeat does not guarantee that the
watchdog won't trigger a reset, but at least it reduces the chances to be
in such a case.

Signed-off-by: Boris BREZILLON <b.brezillon@xxxxxxxxxxx>

Reviewed-by: Guenter Roeck <linux@xxxxxxxxxxxx>


--
To unsubscribe from this list: send the line "unsubscribe linux-watchdog" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html