Re: [PATCH RFC v1 1/2] genirq/affinity: add support for limiting managed interrupts

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 




> 2024年10月31日 18:35,Thomas Gleixner <tglx@xxxxxxxxxxxxx> 写道:
> 
> On Thu, Oct 31 2024 at 15:46, guanjun@xxxxxxxxxxxxxxxxx wrote:
>> #ifdef CONFIG_SMP
>> 
>> +static unsigned int __read_mostly managed_irqs_per_node;
>> +static struct cpumask managed_irqs_cpumsk[MAX_NUMNODES] __cacheline_aligned_in_smp = {
>> +	[0 ... MAX_NUMNODES-1] = {CPU_BITS_ALL}
>> +};
>> 
>> +static void __group_prepare_affinity(struct cpumask *premask,
>> +				     cpumask_var_t *node_to_cpumask)
>> +{
>> +	nodemask_t nodemsk = NODE_MASK_NONE;
>> +	unsigned int ncpus, n;
>> +
>> +	get_nodes_in_cpumask(node_to_cpumask, premask, &nodemsk);
>> +
>> +	for_each_node_mask(n, nodemsk) {
>> +		cpumask_and(&managed_irqs_cpumsk[n], &managed_irqs_cpumsk[n], premask);
>> +		cpumask_and(&managed_irqs_cpumsk[n], &managed_irqs_cpumsk[n], node_to_cpumask[n]);
> 
> How is this managed_irqs_cpumsk array protected against concurrency?

My intention was to allocate up to `managed_irq_per_node` cpu bits from `managed_irqs_cpumask[n]`,
even if another task modifies some of the bits in the `managed_irqs_cpumask[n]` at the same time.

> 
>> +		ncpus = cpumask_weight(&managed_irqs_cpumsk[n]);
>> +		if (ncpus < managed_irqs_per_node) {
>> +			/* Reset node n to current node cpumask */
>> +			cpumask_copy(&managed_irqs_cpumsk[n], node_to_cpumask[n]);
> 
> This whole logic is incomprehensible and aside of the concurrency
> problem it's broken when CPUs are made present at run-time because these
> cpu masks are static and represent the stale state of the last
> invocation.

Sorry, I realize there is indeed a logic issue here (caused by developing on 5.10 LTS and rebase to the latest linux-next).

> 
> Given the limitations of the x86 vector space, which is not going away
> anytime soon, there are only two options IMO to handle such a scenario.
> 
>   1) Tell the nvme/block layer to disable queue affinity management
> 
>   2) Restrict the devices and queues to the nodes they sit on

I have tried fixing this issue through nvme driver, but later discovered that the same issue exists with virtio net.
Therefore, I want to address this with a more general solution.

Thanks,
Guanjun

> 
> Thanks,
> 
>        tglx






[Index of Archives]     [KVM Development]     [Libvirt Development]     [Libvirt Users]     [CentOS Virtualization]     [Netdev]     [Ethernet Bridging]     [Linux Wireless]     [Kernel Newbies]     [Security]     [Linux for Hams]     [Netfilter]     [Bugtraq]     [Yosemite Forum]     [MIPS Linux]     [ARM Linux]     [Linux RAID]     [Linux Admin]     [Samba]