Re: [PATCH v8 07/10] iommufd: Fault-capable hwpt attach/detach/replace

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Fri, Oct 18, 2024 at 09:58:37AM +0800, Baolu Lu wrote:
> On 2024/10/17 21:08, Jason Gunthorpe wrote:
> > On Thu, Oct 17, 2024 at 08:35:24PM +0800, Zhangfei Gao wrote:
> > 
> > > Yes, you are right
> > >   I am using SRIOV vf and stall feature, so is_virtfn == true
> > > 
> > > Our ACC devices are fake pci endpoint devices which supports stall,
> > > And they also supports sriov
> > > 
> > > So I have to ignore the limitation.
> > I see, so that is more complicated.
> > 
> > Lu, what do you think about also checking if the PCI function has PRI
> > ? If not PRI assume the fault is special and doesn't follow PRI rules?
> > 
> > Or maybe we can have the iommu driver tag the event as a PRI/not-PRI
> > fault?
> 
> This limitation applies to PRI on PCI/SRIOV VFs because the PRI might be
> a shared resource and current iommu subsystem is not ready to support
> enabling/disabling PRI on a VF without any impact on others.
> 
> In my understanding, it's fine to remove this limitation from the use
> case of non-PRI on SRIOV VFs. Perhaps something like below?
> 
> 	if (dev_is_pci(dev)) {
> 		struct pci_dev *pdev = to_pci_dev(dev);
> 		if (pdev->is_virtfn && pci_pri_supported(pdev))
> 			return -EINVAL;
> 	}

Makes sense to me

Thanks,
Jason




[Index of Archives]     [KVM Development]     [Libvirt Development]     [Libvirt Users]     [CentOS Virtualization]     [Netdev]     [Ethernet Bridging]     [Linux Wireless]     [Kernel Newbies]     [Security]     [Linux for Hams]     [Netfilter]     [Bugtraq]     [Yosemite Forum]     [MIPS Linux]     [ARM Linux]     [Linux RAID]     [Linux Admin]     [Samba]

  Powered by Linux