From: Leonard Dallmayr <leonard.dallmayr@xxxxxxxxxxx> The device IMST USB-Stick for Smart Meter is a rebranded iM871A-USB Wireless M-Bus USB-adapter. It is used to measure smart meters for electricity, heating, water, etc. Signed-off-by: Leonard Dallmayr <leonard.dallmayr@xxxxxxxxxxx> --- drivers/usb/serial/cp210x.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/usb/serial/cp210x.c b/drivers/usb/serial/cp210x.c index 1e61fe043171..099cde4974a3 100644 --- a/drivers/usb/serial/cp210x.c +++ b/drivers/usb/serial/cp210x.c @@ -146,6 +146,7 @@ static const struct usb_device_id id_table[] = { { USB_DEVICE(0x10C4, 0x85F8) }, /* Virtenio Preon32 */ { USB_DEVICE(0x10C4, 0x8664) }, /* AC-Services CAN-IF */ { USB_DEVICE(0x10C4, 0x8665) }, /* AC-Services OBD-IF */ + { USB_DEVICE(0x10C4, 0x87ed) }, /* IMST USB-Stick for Smart Meter */ { USB_DEVICE(0x10C4, 0x8856) }, /* CEL EM357 ZigBee USB Stick - LR */ { USB_DEVICE(0x10C4, 0x8857) }, /* CEL EM357 ZigBee USB Stick */ { USB_DEVICE(0x10C4, 0x88A4) }, /* MMB Networks ZigBee USB Device */ -- 2.43.0