On Mon, Oct 30, 2023 at 12:45:54PM +0200, Mathias Nyman wrote: > On 27.10.2023 18.20, Hardik Gajjar wrote: > > - The HCD address_device callback now accepts a user-defined timeout value > > in milliseconds, providing better control over command execution times. > > - The default timeout value for the address_device command has been set > > to 5000 ms, aligning with the USB 3.2 specification. However, this > > timeout can be adjusted as needed. > > - The xhci_setup_device function has been updated to accept the timeout > > value, allowing it to specify the maximum wait time for the command > > operation to complete. > > - The hub driver has also been updated to accommodate the newly added > > timeout parameter during the SET_ADDRESS request. > > > > Signed-off-by: Hardik Gajjar <hgajjar@xxxxxxxxxxxxxx> > > For the xhci parts > > Reviewed-by: Mathias Nyman <mathias.nyman@xxxxxxxxxxxxxxx> > > @Greg KH, Friendly reminder. Thanks, Hardik