Hi Heikki, On Thu, Oct 28, 2021 at 02:55:32PM +0300, Heikki Krogerus wrote: > On Tue, Oct 26, 2021 at 11:48:42PM -0700, Jack Pham wrote: > > The intent of ucsi_get_src_pdos() is to obtain the source's PDOs > > in order to provide the power_supply object the required data to > > report the mininum, maximum and currently operating voltage & > > current should a PD contract be in place. > > > > If however, the port is operating as a PD source, this call would > > invoke GET_PDOS on the partner causing the PPM to send a > > Get_Source_Caps PD message to the port partner which may not make > > sense especially if the partner is not a dual-power role capable > > device. Further, it has been observed that certain DisplayPort > > adapter cables (which are power sink-only devices) even fail to > > bring up the display link after receiving a Get_Source_Caps > > message, suggesting they can't cope well with an unsupported PD > > message to the point that it renders them functionally inoperable. > > > > Fix this by checking the connector status flags for the power > > direction and use this to decide whether to send the GET_PDOs > > query to the partner or the port. This also helps to make the > > power_supply VOLTAGE_{MIN,MAX,NOW} and CURRENT_{MAX,NOW} > > properties more consistent when the port is in source mode. > > > > Signed-off-by: Jack Pham <quic_jackp@xxxxxxxxxxx> > > --- > > Hi Heikki, > > > > Was wrestling with how exactly to do this. The other approach I was > > thinking was to not even do GET_PDOs at all if operating as a source, > > but that would also mean we'd need to add similar checking to the > > VOLTAGE/CURRENT property getters in psy.c so that they would not > > return incorrect/stale data. Since the ONLINE property will already > > be 0 anyway it may make more sense to invalidate the rest of the props? > > > > The patch below is concise though...so that's what I went with ;) > > Would it still make sense / help if we had separate power supplies > registered for the port-source, port-sink, partner-source and > partner-sink? The name "power_supply" of the class to me implies a source :). So I can see perhaps having separate port-source and partner-source supplies making sense; they would effectively be mutually exclusive as only one of the pair would be "online" at a time when a partner is present depending on the power direction. But I'm not sure I see a use for having port-sink/partner-sink objects though. While the VOLTAGE_NOW / CURRENT_NOW properties might be redundantly reporting the same value from corresponding -source objects, would there be different MIN/MAX values which are obtained from Get_Sink_Caps? > I also think we need to unify these power supplies so that tcpm and > ucsi (and others) always register the same power supplies. I like that idea too! Thanks, Jack